Basement Egress Window Building Codes

buildingcodepages001012.gif

Basement Egress Window Laws and Codes

Egress Window Permit Requirement Research Tool
for the Columbus, Ohio Metropolitan Area

One and Two Family Dwelling Code Section 310.2 - 310.2.2 Emergency egress required.
Ohio Residential Code (ORC) Section 1026
International Residential Code (IRC- 2006) Section R 310.1 - 310.5 Egress/Rescue Opening Code Requirements for One- and Two-Family Dwellings.

Ohio Residential Code (ORC) Section 1026 Emergency Escape and Rescue

SECTION 1026 EMERGENCY ESCAPE AND RESCUE

1026.1 General. In addition to the means of egress required by this chapter, provisions shall be made for emergency escape and rescue in Group R and I-1 occupancies. Basements and sleeping rooms below the fourth story above grade plane shall have at least one exterior emergency escape and rescue opening in accordance with this section. Where basements contain one or more sleeping rooms, emergency egress and rescue openings shall be required in each sleeping room, but shall not be required in adjoining areas of the basement. Such openings shall open directly into a public way or to a yard or court that opens to a public way.
Exceptions:

1.In other than Group R-3 occupancies, buildings equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1 or 903.3.1.2.

2.In other than Group R-3 occupancies, sleeping rooms provided with a door to a fire-resistance-rated corridor having access to two remote exits in opposite directions.

3.The emergency escape and rescue opening is permitted to open onto a balcony within an atrium in accordance with the requirements of Section 404, provided the balcony provides access to an exit and the dwelling unit or sleeping unit has a means of egress that is not open to the atrium.

4. Basements with a ceiling height of less than 80 inches (2032 mm) shall not be required to have emergency escape and rescue windows.

5.High-rise buildings in accordance with Section 403.

6.Emergency escape and rescue openings are not required from basements or sleeping rooms that have an exit door or exit access door that opens directly into a public way or to a yard, court or exterior exit balcony that opens to a public way.

7.Basements without habitable spaces and having no more than 200 square feet (18.6 m2) in floor area shall not be required to have emergency escape windows.

1026.2 Minimum size. Emergency escape and rescue openings shall have a minimum net clear opening of 5.7 square feet (0.53 m2).
Exception: The minimum net clear opening for emergency escape and rescue grade-floor openings shall be 5 square feet (0.46 m2).
1026.2.1 Minimum dimensions. The minimum net clear opening height dimension shall be 24 inches (610 mm). The minimum net clear opening width dimension shall be 20 inches (508 mm). The net clear opening dimensions shall be the result of normal operation of the opening.

1026.3 Maximum height from floor. Emergency escape and rescue openings shall have the bottom of the clear opening not greater than 44 inches (1118 mm) measured from the floor.

1026.4 Operational constraints. Emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. Bars, grilles, grates or similar devices are permitted to be placed over emergency escape and rescue openings provided the minimum net clear opening size complies with Section 1026.2 and such devices shall be releasable or removable from the inside without the use of a key, tool or force greater than that which is required for normal operation of the escape and rescue opening. Where such bars, grilles, grates or similar devices are installed in existing buildings, smoke alarms shall be installed in accordance with Section 907.2.10 regardless of the valuation of the alteration.

1026.5 Window wells. An emergency escape and rescue opening with a finished sill height below the adjacent ground level shall be provided with a window well in accordance with Sections 1026.5.1 and 1026.5.2.

1026.5.1 Minimum size. The minimum horizontal area of the window well shall be 9 square feet (0.84 m2), with a minimum dimension of 36 inches (914 mm). The area of the window well shall allow the emergency escape and rescue opening to be fully opened.

1026.5.2 Ladders or steps. Window wells with a vertical depth of more than 44 inches (1118 mm) shall be equipped with an approved permanently affixed ladder or steps. Ladders or rungs shall have an inside width of at least 12 inches (305 mm), shall project at least 3 inches (76 mm) from the wall and shall be spaced not more than 18 inches (457 mm) on center (o.c.) vertically for the full height of the window well. The ladder or steps shall not encroach into the required dimensions of the window well by more than 6 inches (152 mm). The ladder or steps shall not be obstructed by the emergency escape and rescue opening. Ladders or steps required by this section are exempt from the stairway requirements of Section 1009.


Effective: 11/01/2007

R.C. 119.032 review dates: 07/01/2012

Promulgated Under: 119.03

Statutory Authority: 3781.10(A)

Rule Amplifies: 3781.10, 3781.11, 3791.04

Prior Effective Dates: 1/1/94, 7/1/95, 2/1/96, 3/1/98, 1/1/02, 3/1/05, 9/6/05, 7/1/07
Back to top of page.

One and Two Family Dwelling Code Section 310.2 - 312.2 Emergency egress required.

310.2 Emergency egress required. Every sleeping room shall have at least one openable window or exterior door approved for emergency egress or rescue. The units must be operable from the inside to a full clear opening without the use of a key or tool. Where windows are provided as a means of egress or rescue they shall have a sill height of not more than 44 inches (1118 mm) above the floor.

310.2.1 Minimum Size. All egress or rescue windows from sleeping rooms must have a net clear opening of 5.7 square feet (0.530 m2). The minimum net clear opening height shall be 22 inches (559 mm). The minimum net clear opening width shall be 20 inches (508 mm).

Exception: Grade floor window may have a minimum net clear opening of 5 square feet (320 mm2).

310.2.2 Bars, grills and screens. bars, grills, screens or other obstructions placed over emergency escape windows shall be releasable from the inside without the use of a key or tool.

Back to top of page.

International Residential Code (IRC- 2006) Section R 310.1 - 310.5 Egress/Rescue Opening Code Requirements for One- and Two-Family Dwellings.

EMERGENCY ESCAPE AND RESCUE REQUIRED SECTION: R 310.1
Basements and every sleeping room shall have at least one operable emergency and rescue opening. Such opening shall open directly into a public street, public alley, yard or court. Where basements contain one or more sleeping rooms, emergency egress and rescue openings shall be required in each sleeping room, but shall not be required in adjoining areas of the basement. Where emergency escape and rescue openings are provided they shall have a sill height of not more than 44 inches (1118 mm) above the floor. Where a door opening having a threshold below the adjacent ground elevation serves as an emergency escape and rescue opening and is provided with a bulkhead enclosure, the bulkhead enclosure shall comply with Section R310.3. The net clear opening dimensions required by this section shall be obtained by the normal operation of the emergency escape and rescue opening from the inside. Emergency escape and rescue openings with a finished sill height below the adjacent ground elevation shall be provided with a window well in accordance with Section R310.2.

MINIMUM OPENING AREA: SECTION: R 310.1.1
All emergency escape and rescue openings shall have a minimum net clear opening of 5.7 square feet (0.530 m2).
Exception: Grade floor openings shall have a minimum net clear opening of 5 square feet (0.465 m2).

MINIMUM OPENING HEIGHT: R 310.1.2
The minimum net clear opening height shall be 24 inches (610 MM).

MINIMUM OPENING WIDTH: R 310.1.3
The minimum net clear opening width shall be 20 inches (508 mm).

OPERATIONAL CONSTRAINTS: R 310.1.4
Emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools or special knowledge.

WINDOW WELLS: SECTION: R310.2
The minimum horizontal area of the window well shall be 9 square feet (0.9 m2), with a minimum horizontal projection and width of 36 inches (914 mm). The area of the window well shall allow the emergency escape and rescue opening to be fully opened.
Exception: The ladder or steps required by SECTION R 310.2.1 shall be permitted to encroach a maximum of 6 inches (152 mm) into the required dimensions of the window well.

LADDER AND STEPS: SECTION: R 310.2.1
Window wells with a vertical depth greater than 44 inches (1118 mm) shall be equipped with a permanently affixed ladder or steps usable with the window in the fully open position. Ladders or steps required by this section shall not be required to comply with Sections R311.5 and R311.6. Ladders or rungs shall have an inside width of at least 12 inches (305 mm), shall project at least 3 inches (76mm) from the wall and shall be spaced not more than 18 inches (457 mm) on center vertically for the full height of the window well.

BULKHEAD ENCLOSURES: SECTION: R 310.3
Bulkhead enclosures shall provide direct access to the basement. The bulkhead enclosure with the door panels in the fully open position shall provide the minimum net clear opening required by Section R 310.1.1. Bulkhead enclosures shall also comply with Section R 311.5.8.2.

BARS, GRILLS, COVERS, AND SCREENS: SECTION: R 310.3
Bars, grills, covers, screens or similar devices are permitted to be placed over emergency escape and rescue openings, bulkhead enclosures, or window wells that serve such openings, provided the minimum net clear opening size complies with Sections R 310.1.1 to R 310.1.3, and such devices shall be releasable or removable from the inside without the use of a key, tool, special knowledge or force greater than that which is required for normal operation of the escape and rescue opening.

EMERGENCY ESCAPE WINDOWS UNDER DECKS AND PORCHES: SECTION: R 310.5
Emergency escape windows are allowed to be installed under decks and porches provided the location of the deck allow the emergency escape window to be fully opened and provides a path not less than 36 inches (914 mm) in height to a yard or court.